塞曼石墨炉原子吸收法测定废水中低含量锡 |
To Determine Low Content Tinin Waste Water Using Zeeman Graphite Furnace AAS |
|
DOI: |
中文关键词: 原子吸收光谱法 恒温平台石墨炉 锡 废水 |
英文关键词: AAS Stabletemperatureplatform graphitefurnace Tin Wastewater |
基金项目: |
|
摘要点击次数: 1481 |
全文下载次数: 1192 |
中文摘要: |
试验了集恒温平台石墨炉 (ST PF) 于一体的纵向塞曼效应背景校正, 最大功率升温, 钯作为基体改进剂和峰面积积分( A - s )测定废水中低含量锡的新方法。测定结果表明, 锡含量在0 μ g/L~ 100μ g/L范围内呈良好的线性关系, 检测限(3σ)3.5×10 - 11 g, 特征量为9.1×10 - 11 g, 相对标准差小于6%, 回收率在91% ~ 107% 之间。 |
英文摘要: |
New methodto determinelow content Tin in wastewater wastested. Itcombined stabletemperature platform graphitefurnace, undertook correction with verticalZeeman effect background,took palladium as matrix modifier and peak areaintegral. Theresultsindicatedthatthere were a goodlinearrelationship whentheconcentrationof Tin withinthelimitof0μg/L~ 100μ g/L,the detectionlimit(3σ)was3.5×10- 11 g,trait quantity was9.1×10 - 11 g, relativestandard deviation waslessthan 6%,recoveryrate was within 91% ~ 107%. |