内置式热解吸-气相色谱联用检测室内空气中 TVOC |
Total Volatile Organic Compounds Determ ination in Indoor Air by Built-in ThermalDesorption/GC |
|
DOI: |
中文关键词: 总挥发性有机物 内置式热解吸 气相色谱法 室内空气 |
英文关键词: TVOC Built-in thermaldesorption Gaschromatography Indoorair |
基金项目: |
|
摘要点击次数: 1420 |
全文下载次数: 1095 |
中文摘要: |
采用内置式热解吸-气相色谱联用检测室内空气中总挥发性有机物, 介绍了内置式热解吸进样的优点。建立了苯、甲苯、乙酸丁酯、乙苯、对 ( 间 ) 二甲苯、苯乙烯、邻二甲苯、正十一烷等典型有机污染物的外标曲线, 各组分相关系数R 2 为 0.999 2 ~ 1, 考察了方法重复性,6 次平行试验的RSD为 0.8% ~ 1.4% 。 |
英文摘要: |
The GC with built-inthermaldesorptionwasapplied fordetermination oftotalvolatileorganiccom poundsin indoorair. The advantageofbuilt-in thermaldesorptioninjection wasdescribed. Thestandard curvesof typicalorganicpollutantswereestablished such asBenzene, Toluene, Butylacetate, Ethylbenzene,p-Xylene, m-Xylene,o-Xylene, Styreneand Undecane. Thecorrelation coefficientsofcompounds R 2 ranged from 0.999 2to1. Therepeatability ofmethod wasobserved and RSD ofsix paralleltestsranged from 0.8% to1.4%. |