| 高效液相色谱-电喷雾电离质谱法测定地表水中微囊藻毒素 |
| Determination of MC-LR in Surface Water by High Performance Liquid Chromatography with Mass Spectrometry |
| |
| DOI: |
| 中文关键词: |
| 英文关键词: |
| 基金项目: |
|
| 摘要点击次数: 2259 |
| 全文下载次数: 1964 |
| 中文摘要: |
| 采用固相萃取-高效液相色谱-电喷雾电离质谱法测定饮用水源地地表水中痕量微囊藻毒素MC-LR,优化了色谱和质谱条件,以甲醇/水(含0.1%甲酸)混合溶液(体积比60∶40)为流动相,选择定量离子质荷比(m/z)996.3。方法在0.100 mg/L~2.00 mg/L范围内线性良好,检出限为0.02 μg/L,空白水样加标回收率为(96.25.4)%。 |
| 英文摘要: |
| Trace Microcystin (MC-LR) in drinking source surface water was determined by HPLC-ESI-MS with solid phase extraction and test conditions of chromatography and mass was optimized. The results showed that mobile solution [V(methanol)∶V(water)=60∶40] which contained 0.1% methanoic acid, selective quantity ion (m/z=996.3). Good linearity of the method was obtained in range from 0.100 mg/L to 2.00 mg/L,the detection limits 0.02 μg/L, spiked standard recoveries of blank samples (96.25.4)%. |
|