Intercomparison tests for Integrated RF Field Intensity of National Radiation Environmental Monitoring Network Program (2011) were described. The 78 measured values of intercomparion tests from 36 institutes were evaluated with robust statistics by organizer. Results showed that the 87.3% measured values were satisfactory, 7.7% questionable, and 5% unsatisfactory. Effects of several factors on integrated RF field intensity were discussed for example measuring equipment. The results of tests had objectively reflected the technological level of measurement, which would help with quality assurance in the future. |