025-83701931 设为首页 加入收藏
文章摘要
煤质样品中汞的直接测定
Direct Determination of Mercury in Coal Samples
  
DOI:
中文关键词:   DMA-80型直接测汞仪  冷原子吸收光谱法  煤质样品
英文关键词: Mercury  DMA-80 Direct mercury technology  CAAS  Coal samples
基金项目:
作者单位
高小青 甘肃省环境监测中心站 
常璐 甘肃省环境监测中心站 
摘要点击次数: 1419
全文下载次数: 1759
中文摘要:
      采用DMA-80型直接测汞仪测定煤中汞含量,样品经过筛(100目)预处理,干燥温度和时间分别为200 ℃和30 s,分解温度和时间分别为650 ℃和90 s,基体元素对测定无明显干扰。方法在高质量浓度(0.200 mg/L~10.0 mg/L)和低质量浓度(0.400 μg/L~200 μg/L)范围内均线性良好,对0.100 g煤质样品的最低检出限为0.4 μg/kg,平行测定的RSD<5%,加标回收率>97%,与原子荧光法的测定结果相一致。
英文摘要:
      DMA-80 direct mercury technology was applied to determine the concentration of mercury in coal samples.The sample was pretreated with a 100 mesh sieve before analysis.The optimized conditions of drying temperature and time are 200 ℃and 30 s,and decomposition temperature and time are 650 ℃and 90 s,respectively.There is no obvious interference of matrix elements on mercury analysis.The method shows good linearity in both higher concentration (0.200 mg/L~10.0 mg/L) and lower concentration (0.400 μg/L~200 μg/L) of mercury.For 0.100 g coal sample,the detection limit of 0.4 μg/kg was obtained.RSD of parallel determination is less than 5%,and the spiked recovery is more than 97%.The analytical results are in good agreement with the values measured by atomic fluorescence spectrometry.
查看全文   查看/发表评论  下载PDF阅读器
关闭