025-83701931 设为首页 加入收藏
文章摘要
固相萃取-高效液相色谱法同时测定饮用水中苯胺和联苯胺
Simultaneous Determination of Aniline and Benzidine in Drinking Water by High Performance Liquid Chromatography
  
DOI:
中文关键词: 苯胺  联苯胺  固相萃取  高效液相色谱法  饮用水
英文关键词: Aniline  Benzidine  Solid phase extraction  High performance liquid chromatography  Drinking water
基金项目:
作者单位
张丽 连云港市环境监测中心站 
刘玉侠 连云港市环境监测中心站 
摘要点击次数: 1438
全文下载次数: 1122
中文摘要:
      用Waters Oasis MCX固相萃取小柱富集水中的苯胺和联苯胺,以2%氨水-甲醇混合溶液为洗脱液,采用高效液相色谱法DAD检测器在285 nm波长下测定。苯胺和联苯胺分别在0 mg/L~100 mg/L和0 mg/L~10.0 mg/L范围内线性良好,检出限分别为0.3 μg/L和0.1 μg/L,饮用水加标平行测定6次的RSD分别为0.9%和0.3%,回收率分别为98.3%~99.1%和97.6%~102%。
英文摘要:
      Waters Oasis MCX solid phase extraction column was used for the enrichment of aniline and benzidine in drinking water.HPLC equipped with DAD was used for quantitation at 285 nm. The recoveries of two target compounds were between 97.6%~102%, and the RSDs were between 0.3% and 0.9%, the determined range of aniline was 0 mg/L~100 mg/L,and benzidine was 0 mg/L~10.0 mg/L. The minimum detectable concentration was 0.1 μg/L~0.3 μg/L. This method was applied in drinking water to the determination of aniline and benzidine, and the result was satisfactory.
查看全文   查看/发表评论  下载PDF阅读器
关闭