025-83701931 设为首页 加入收藏
文章摘要
全自动石墨消解-原子荧光法测定土壤中砷和汞
Determination of Arsenic and Mercury in Soil by Atomic Fluorescence Spectrometry with the Full Automatic Graphite Digestion Method
  
DOI:
中文关键词:     全自动石墨消解  原子荧光法  土壤
英文关键词: Arsenic  Mercury  Automatic graphite digestion system  Atomic fluorescence spectrometry  Soils
基金项目:
作者单位
张启辉 马鞍山市环境监测中心站 
孙维 马鞍山市环境监测中心站 
摘要点击次数: 1785
全文下载次数: 0
中文摘要:
      采用全自动石墨消解仪代替水浴锅加热王水消解法处理土壤样品,用原子荧光法测定消解液中的砷和汞。该方法在0 μg/L~20.0 μg/L范围内线性良好,测定有证标准土壤样品的结果均在标准值允许范围内,砷、汞测定结果的RSD分别为2.5%~4.8%、2.9%~5.4%,比王水消解法的测定结果更靠近标准值,实际土壤样品的加标回收率分别为94.6%~104%、92.6%~105%。
英文摘要:
      Automatic graphite digestion instrument method, instead of aqua regia digestion with water bath heating,was adopted as the pretreatment method for soil samples, then arsenic and mercury in the digestion solution was determined by atomic fluorescence spectrometry. This method had good linearity in the range of 0 μg/L~20.0 μg/L,and the determination results of certified standard soil samples were within the permissible range.RSDs of arsenic and mercury were 2.5%~4.8% and 2.9%~5.4%. Also,the determination results of automatic graphite digestion method were more close to the standard value than the determination results of aqua regia digestion method. The recovery of arsenic and mercury in the practical soil samples were 94.6%~104% and 92.6%~105%.
查看全文   查看/发表评论  下载PDF阅读器
关闭