In this paper, the emission limits in Standard for pollution control on the municipal solid waste incineration (GB 18485—2001) and (GB 18485—2014) were compared respectively, and the control measures of flue gases pollutants, such as dioxin, heavy metals, acid gases, smoke and dust, carbon oxides ect. were discussed. According to the “three simultaneous” check and accept monitoring data (2010—2014) from some garbage incineration plants in Zhejiang Province, it indicated that the technique of “3T+E” incineration process+SNCR denitration+semidry deacidification process+activated carbon spray+bag filter dust removal, can meet the demands of denitration, deacidification and removal of dust, heavy metals, dioxins from flue gases simultaneously. |