顶空气相色谱法测定漓江底泥中的三氯乙烯和四氯乙烯 |
Determination of Trichloroethylene and Tetrachloroethylene in Li River Sediments by Headspace Gas Chromatography |
|
DOI: |
中文关键词: 三氯乙烯 四氯乙烯 顶空气相色谱法 底泥 |
英文关键词: Trichloroethylene Tetrachloroethylene Headspace gas chromatography Sediment |
基金项目:桂林市环境监测中心站科研孵化基金资助项目(FH201502) |
|
摘要点击次数: 1088 |
全文下载次数: 0 |
中文摘要: |
采用NaCl溶液提取,顶空气相色谱法测定底泥中的三氯乙烯和四氯乙烯,方法在0.098 ng/L~1.03 ng/L范围内线性良好,三氯乙烯和四氯乙烯的方法检出限分别为0.013 ng/g和0.016 ng/g。对空白样品做3个质量比水平的加标回收试验,7次测定结果的RSD为2.0%~3.8%,平均加标回收率为94.0%~109%。将该方法用于桂林市漓江底泥样品的测定,结果三氯乙烯和四氯乙烯均为未检出,实际样品加标回收率为92.0%~107%。 |
英文摘要: |
Trichloroethylene and tetrachloroethylene in sediment were extracted by 10% NaCl solution, and determined by headspace gas chromatography. Results showed that good linearity was obtained in the concentration range of 0.098 ng/L~1.03 ng/L. The MDL of trichloroethylene and tetrachloroethylene were 0.013 ng/kg and 0.016 ng/kg, respectively.7 times of spiked blank tests were carried out in 3 concentration level, the RSDs of 7 tests ranged from 2.0%~3.8%, the average recoveries were in the range of 94.0%~109%. The test results of sediment samples from Li River in Guilin showed that trichloroethylene and tetrachloroethylene were not detected, the recoveries of spiked sample were in the range of 92%~107%. |