不同前处理方法对GC MS法测定水中多种SVOCs效率的影响 |
Effect of Different Pretreatment Methods on Determination Efficiency of SVOCs in Water by GC MS |
|
DOI: |
中文关键词: 半挥发性有机污染物 固相萃取 气相色谱质谱联用法 水质 |
英文关键词: SVOCs SPE GC MS Water quality |
基金项目:山东省2015年度31个省级地质勘查基金资助项目(SDZS-2015-GTT01) |
|
摘要点击次数: 1117 |
全文下载次数: 0 |
中文摘要: |
通过对比液液萃取法、大孔吸附树脂法、固相萃取膜法、动态活性炭吸附法和固相萃取小柱法的试验效能,最终选择固相萃取小柱法作为测定水中7大类27种SVOCs的前处理方法,并对其进一步优化。试验表明,该方法在10.0 μg/L~500 μg/L范围内线性良好,方法检出限为0.003 1 μg/L~0.03 μg/L,空白加标样的回收率为70.9%~93.8%,RSD≤11.2%。 |
英文摘要: |
By comparing the test effectiveness of liquid liquid extraction, macroporous resin adsorption, membrane extraction, dynamic activated carbon adsorption and SPE, SPE was finally chosen as the pretreatment method for determining 27 kinds in 7 categories of SVOCs, and the test conditions were further optimized. Experiment results showed that this method had good linearity in the range of 10.0 μg/L~500 μg/L, the detection limits were 0.003 1 μg/L~0.03 μg/L, RSD≤11.2%, the recoveries ranged from 70.9%~93.8%. |
查看全文
查看/发表评论 下载PDF阅读器 |
关闭 |