燃煤电厂烟气中铅的测定方法初探 |
Preliminary Study on Test Method for Lead in Flue Gas from Coal fired Power Plant |
|
DOI: |
中文关键词: 铅 测定方法 燃煤电厂 烟气 |
英文关键词: Lead Test method Coal fired power plant Flue gas |
基金项目:国家重点研发计划基金资助项目(2018YFC0213903);广东省科技计划基金资助项目(20180208) |
|
摘要点击次数: 1006 |
全文下载次数: 174 |
中文摘要: |
采用过滤法与吸收法联用的采样方法,测定燃煤电厂烟气中Pb,并通过试验考察4种不同的吸收液和4种不同采样流量对测定的影响。结果表明:01 mol/L HNO3、〖JP3〗体积分数为5%的HNO3+10%的H2O2和体积分数为16%的HNO3+〖JP〗25%的HCl 3种吸收液均对Pb起到良好的捕集作用,且测定结果相近。采样流量控制在20 L/min吸收效果最好。 |
英文摘要: |
Pb emissions in the flue gas from coal fired power plant were determined by combining the sampling methods of filtration and absorption. The testing effectiveness of 4 kinds of absorbent and 4 sampling flows was studied through experiments. The results showed that 3 kinds of absorbent, including 0.1 mol/L HNO3, 5% V/V HNO3+10% V/V H2O2 and 1.6% V/V HNO3+2.5% V/V HCl, had good absorption effects, and the results were similar. The absorption effect was the best when the sampling flow was 20 L/min. |