|
| 基于污水厂监测数据的反硝化脱氮影响因素分析 |
| Analysis on Influencing Factors of Denitrification based on Monitoring Data from Sewage Plant |
| |
| DOI: |
| 中文关键词: 反硝化脱氮 影响因素 污水处理厂 |
| 英文关键词: Denitrification Influencing factor Sewage plant |
| 基金项目:安徽省重点研究与开发计划基金资助项目(1804a0802191) |
|
| 摘要点击次数: 980 |
| 全文下载次数: 263 |
| 中文摘要: |
| 以污水厂长序列运行数据为基础,反推脱氮实际影响因素,开展反硝化脱氮试验。结果表明,在2019年4月前后TN出水平均浓度降低58%;受季节和污水厂升级改造影响,温度由15 ℃升高至25 ℃,混合液悬浮固体质量浓度(MLSS)由4 300 mg/L增至8 000 mg/L,活性污泥成分增加,脱氮效果提升;BOD5/TN和pH值等变化相对稳定,温度、MLSS是影响该污水处理厂反硝化脱氮的主要因素;当反应温度为(25±5)℃,pH值为75±02,MLSS为4 800 mg/L时,反硝化脱氮效果最佳,硝酸盐氮去除率达91%。 |
| 英文摘要: |
| Based on the long term operation data from a sewage plant,the actual influencing factors of denitrification were studied through denitrification experiments. The results showed that after treatment,the average concentration of total nitrogen in water decreased by 58% around April, 2019. Influenced by seasonal change and the upgrading and rebuilding of the sewage plant, the temperature increased from 15 ℃ to 25 ℃, mixed liquor suspended solids (MLSS) increased from 4 300 mg/L to 8 000 mg/L, the component of activated sludge and the effect of denitrification increased. The changes of BOD5/TN and pH value were relatively stable. Temperature and MLSS were the main factors affecting denitrification. When the reaction temperature was (25±5)℃, pH value was 7.5±0.2,and MLSS was 4 800 mg/L, the denitrification effect was the best, the removal rate of nitrate nitrogen reached 91%. |
|
查看全文
查看/发表评论 下载PDF阅读器 |
| 关闭 |