雄安新区环境电磁辐射水平初步监测 |
Preliminary Monitoring on Environmental Electromagnetic Radiation Level in Xiong,an New Area |
|
DOI: |
中文关键词: 电磁辐射 电场强度 辐射监测 雄安新区 |
英文关键词: Electromagnetic radiation Electric intensity Radiation monitoring Xiong,an New Area |
基金项目:国家重点研发计划基金资助项目(2018YFC1602500) |
|
摘要点击次数: 541 |
全文下载次数: 128 |
中文摘要: |
对雄安新区电磁辐射水平进行监测和分析,结果表明:该地区一般环境电场强度为未检出~1.03 V/m,基站周围电场强度为0.36 V/m~1.08 V/m,广播电视塔周围电场强度为0.65 V/m~3.19 V/m,均低于《电磁环境控制限值》(GB 8702—2014)中对公众暴露控制限值的要求。表明雄安新区电磁辐射水平总体良好,处于正常环境本底水平。 |
英文摘要: |
The monitoring and analysis of the electromagnetic radiation level in Xiong,an New Area showed that the general environmental electric field intensities in this area were from undetected to 1.03 V/m, the electric field intensities were between 0.36 V/m and 1.08 V/m around base stations, and between 0.65 V/m and 3.19 V/m around radio and television towers, all were below the requirements of the public exposure control limits in “Controlling limits for electromagnetic environment” (GB 8702—2014). It indicated that the electromagnetic radiation level in Xiong,an New Area was generally good and at the normal environmental background level. |