| 中文摘要: |
| 采用正压罐采样预浓缩GC/MS法同时测定空气中16种卤代烃,通过优化试验条件,使16种痕量卤代烃在30min内实现分离,目标物分别在40 pmol/mol~200 pmol/mol和5 pmol/mol~100 pmol/mol范围内线性良好,方法检出限为4 pmol/mol~55 pmol/mol。标准气体6次测定结果的RSD为1.0%~7.2%,空白样品加标回收率为72.5%~125%。 |
| 英文摘要: |
| 16 halogenated hydrocarbons in air were simultaneously determined by canister collecting-preconcentration-GC/MS. By optimizing the test conditions, 16 trace halogenated hydrocarbons were separated within 30 min. The target objects had good linearity in the range of 40 pmol/mol to 200 pmol/mol and 5 pmol/mol to 100 pmol/mol. The method detection limits were from 4 pmol/mol to 55 pmol/mol. The RSDs of 6 measurements of standard gas ranged from 1.0% to 7.2%. The recoveries of blank samples were from 72.5% to 125%. |
|