全自动固相萃取气质联用法测定废水中硝基苯类化合物 |
Determination of Nitrobenzene Compounds in Wastewater by Automatic Solid Phase Extraction-Gas Chromatography-Mass Spectrometry |
|
DOI: |
中文关键词: 硝基苯类化合物 固相萃取 气质联用法 工业废水 |
英文关键词: Nitrobenzene compounds Solid phase extraction GC-MS Industrial wastewater |
基金项目:天津市重点研发计划基金资助项目(19YFZCSN01330);中央级公益性科研院所基本科研业务费专项基金资助项目(K-JBYWF-2019-QR03) |
|
摘要点击次数: 328 |
全文下载次数: 199 |
中文摘要: |
采用全自动固相萃取处理废水,气相色谱-质谱联用法测定废水中的15种硝基苯类化合物,通过优化试验条件,使方法在0.100mg/L~10.0mg/L范围内线性良好。方法检出限为0.012μg/L~0.038μg/L,标准溶液11次测定结果的RSD为1.0%~7.5%。对实际水样做2个质量浓度水平的加标回收试验,平均加标回收率为78.0%~107%。 |
英文摘要: |
Fifteen nitrobenzene compounds in wastewater were extracted by automatic solid phase and determined by gas chromatography-mass spectrometry(GC-MS). By optimizing the test conditions, the method had good linearity in the range of 0.100mg/L to 10.0mg/L. The method detection limits were from 0.012μg/L to 0.038μg/L. The RSDs of 11 measurements of standard solution were from 1.0% to 7.5%. The average spiked recoveries were from 78.0% to 107% when adding two mass concentration levels to practical samples. |
查看全文
查看/发表评论 下载PDF阅读器 |
关闭 |