液液萃取-高效液相色谱法同时测定水中甲萘威和阿特拉津 |
Simultaneous Determination of Carbaryl and Atrazine in Water by HPLC |
|
DOI: |
中文关键词: 甲萘威 阿特拉津 液液萃取 高效液相色谱法 水质 |
英文关键词: Carbaryl Atrazine Liquid liquid extraction High performance liquid chromatography Water quality |
基金项目: |
|
摘要点击次数: 1764 |
全文下载次数: 1301 |
中文摘要: |
用二氯甲烷萃取水中的甲萘威和阿特拉津,经旋转蒸发和氮吹富集浓缩后,采用高效液相色谱二极管阵列检测器在222 nm波长下测定。甲萘威和阿特拉津在0.100 mg/L~5.00 mg/L范围内线性良好,检出限分别为0.031 μg/L和0.027 μg/L,空白水样加标平均回收率为78.5%~91.7%,平行测定3次的RSD<5%。 |
英文摘要: |
Carbaryl and atrazine in water were extracted by dichloromethane,and then the samples were enriched by rotary evaporator and nitrogen blowing instrument. The extracts were determined by HPLC and detected by a diode array detector at 222 nm.The results indicated that the good linear ranges for carbaryl and atrazine were 0.100 mg/L to 5.00 mg/L and the detection limits were 0.031 μg/L and 0.027 μg/L respectively. For blank samples ,the standard addition recovery was repeatly determinated for 3 times,and the recoveries of the two target compounds were from 78.5% to 91.7%, and RSD were less than 5%. |