CO对定电位电解法测定SO2的影响及对策探讨 |
Influence of Carbon Monoxide on the Determination of Sulfur Dioxide by Constant Potential Electrolysis Method and Countermeasure Research |
|
DOI: |
中文关键词: SO2 CO干扰 定电位电解法 数学模型 修正补偿 |
英文关键词: SO2 CO2 interference Fixed potential by electrolysis method Mathematical model Modifying compensation |
基金项目:中国环境监测总站转型基金资助项目(CNEMC-ZXKY2009-032) |
|
摘要点击次数: 1718 |
全文下载次数: 1729 |
中文摘要: |
采用定电位电解法测定固定污染源废气中SO2,根据CO标准气体干扰SO2测定的规律建立数学模型,并在实验室用CO标气对数学模型进行验证。用该数学模型对5家企业固定污染源废气中SO2监测,将测定结果与碘量法的测定结果比对,绝对误差与相对误差在允许范围内。 |
英文摘要: |
SO2 from stationary sources was determined using the constant potential electrolysis method. A numerical model was established according to the rule of standard CO gas interference, and verification was done in the laboratory through preparation of CO standard gases. The numerical model was applied to monitor SO2 from five enterprises' stationary sources. The absolute error and relative error between the current method and the iodine titration method were within the acceptance scope. |